Mindestmengenregelventile

Minimum Flow Control Valve

Function

It is well known that boiler feedwater pumps and condensate pumps must not drop below a certain minimum flow rate. Otherwise, this would result in unacceptably high heating of the feedwater or condensate. However, during specific boiler operating modes (such as start-up, sliding pressure operation, or low-load operation), the required flow rate is below the pump's minimum capacity. The necessary pump protection is achieved by routing the differential volume back into the feedwater tank or condenser via a pump bypass system—the minimum flow system featuring the minimum flow valve. Consequently, the minimum flow valve functions as a pump safety valve.

Design

Forged valves available in straight-way, angle, or Z-pattern designs, featuring butt-weld ends in accordance with DIN, ANSI, or other international standards.

Benefits

  • Cavitation and erosion minimized via multi-stage pressure drops
  • Unbalanced valve design
  • Fully interchangeable internal components
  • Customized, high-precision flow characteristics tailored to your specific application.
  • High turndown ratio
  • Minimized vibration for exceptionally smooth operation
  • Flexible actuator options: Choose from hydraulic, pneumatic, or electrical type to suit your needs.
  • Fail-safe action: Valve opens automatically upon loss of energy via a dedicated safety accumulator.
     

Proven solutions in practice. Success across a wide range of applications.